Construction
Built into each vacuum tube is a
Sol-titanium coated copper absorber. This ensures a high
absorption rate of solar radiation and a low emission of thermal
radiation
A heat pipe filled
with an evaporator liquid is placed on the absorber. The
heat pipe is connected top to the condenser via a flexible
coupling. The condenser is installed in the Duotec double
pipe heat exchanger. This involves a dry connection, i.e.
the pipes can be rotated or replaced even when the system is
filled and under pressure.
Solar energy is
transferred to the heat pipe, causing the liquid to evaporate.
The vapor rises in the condenser. The heat is transferred
by the double pipe heat exchanger.
|